Call Us
+ 91-11-4666 1111
 
+ 91-11-2646 9031
 
+ 91-11-2646 9108
 
 
 
 
 
 
 
 

Greenline GLX - 1 KVA UPS to 3 KVA Single Phase UPS

 
1KVA to 3KVA Single Phase (with Isolation)
On-line protection for Computer Servers
The Green Line Series is the mighty turbo in 1-3 KVA Single Phase UPS in ONLINE family of Uninterruptible Power Supplies by UNILINE. The Green Line Series provides reliable protection for all high-end applications and is extensively equipped to master all event qualities.

Green Line’s GLX Outstanding features:
Pure sine wave output
Microprocessor control guarantees high reliability
Adopting high frequency full bridge topology for high steady performance
High input power factor correction
Selectable various output range and operating mode
Cold start function
Inbuilt static bypass enhance better protection for critical load
Built-in dry contact / RS-232 / EPO communication port
SNMP allows for web-based remote monitoring management (Optional)
USB communication port (Optional)
Enable to extend runtime with scalable external battery pack
Overload, short-circuit, and overheat protection
Hot-swappable battery design
Compact size with high over all efficiency
Isolation Transformer for Superior Per formation
 
Green Line GLX Series:
True on-line double conversion technology with integrated Static bypass mechanism with Isolation
In normal operation, the Green Line Series converts the mains AC voltage into DC voltage which supplies a battery and an inverter with energy.
The inverter generates a sine wave AC voltage which is permanently available at the output.
If and when power problems strike, the battery delivers the required power to the inverter.
The additional Bypass system integrated into the UPS device guarantees an unprecedented level of power supply security.
In overload conditions the Bypass system automatically switches mains power directly through to the user.
 
Specifications
GREENLINE SERIES TECHNICAL SPECIFICATIONS
Power 1KVA / 700W 2KVA / 1400W, 3KVA / 2100W
Input System Single Phase, Neutral & Earth
Rated Voltage 230 V AC
Voltage Range 138 V to 300 V (0 - 60 % Load), 138 ~ 161 V to 300 V (60 % ~ 80 % Load), 161 ~ 184 V to 300 - 286 V (80 % ~ 100 % Load)
Frequency 50 / 60 Hz +/- 5 Hz (Auto Sensing)
Power Factor > 0.99 @ Full Load
Voltage Range of Bypass 230 V AC ± 10 % (Adjustable)
Output System Single Phase & Earth Ground
Rated Voltage 220 / 230 / 240 V AC
Power Factor 0.7
Voltage Regulation ± 1 %
Normal Mode Freq. 45 ~ 55 (Adjustable)
Battery Mode Freq. 50 ± 0.1 Hz
Inverter Overload Capacity 110 % for 5 Minute
  150 % for 5 Seconds
  0ms (Normal Mode to Battery Mode)
  0ms (Normal Mode to Bypass Mode)
Crest Factor 3: 1
Batteries Voltage 24 V DC / 36 V, 72 V DC, 96 V DC
Charge Current 2A for Internal Batteries, 6A Max. (Adjustable)
Backup Time Dependent on the Capacity of Batteries (Long Backup Time)
Battery Charge Time Charger to 90 % Battery Capacity in 3 Hours (Standard)
Interface Port(s) RS232 + Dry Contact (DB9) + USB (Optional)
Optional Cards SNMP Adaptor
LCD Display Information for Load / Battery / Input / Output and Operating Mode
Audible Alarm Actively Audible Alarm for Utility Failed / Battery Low / Overload Condition
EPO available on front panel
Noise Level <45dB @ 1 Meter ,  <50dB @ 1 Meter
Operating Temp. 0 - 40°C
Storage Temp. -20°C ~ 55°C
Relative Humidity 0 ~ 95 % Humidity, Non - Condensing
Operating Altitude 3,000 Meters
Net Weight (kg) w/o Battery 18, 22, 25
 
Uniline contributes to power industry by manufacturing different series' of online UPS like 1 KVA online UPS, 3 KVA online UPS,1-3 KVA single phase UPS.