Maxipower-IGBT Online UPS System (0.5 KVA to 15 KVA)

 
IGBT Online UPS System (0.5 KVA to 15 KVA)

Complete Blackout and Brownout Protection

According to study by Bells Labs, under voltage & sudden dips represent the majority of power problems. Our IGBT based Online 0.5 - 15 KVA UPS's prevent data loss caused by outrages & brown outs.

Computer Grade Line Conditioning with Isolation

Superior full time inbuilt isolation transformer in all “Uniline” UPS. Output is fully isolated by
double conversion & isolation transformer. No need to have extra isolation transformer as required for  Imported Systems. Remote Monitoring & Control through SNMP (Optional)
 
Salient Features:
IGBT 15 KVA UPS provides wide input window
Generator Compatible
Computer Grade Power
Superior Float Cum Boost Charger
Hi frequency IGBT Based
O/P Distortion < 3%
Inverter Efficiency > 92%
High crest factor > 4 : 1
Crystal controlled output frequency 50 Hz ± 0.01%
Low noise < 50 db upto 10 KVA
Compact & sleek design
Backup up to 8 Hrs.
RS 232 C / SNMP Interface
Tested by Reputed Agencies
 
Network Interface Port
Provided the security of an automatic shut down to all major network operating systems including Novells, Window NT/ Window, Unix etc. Linux (optional kit may be required).
 
Uniline 0.5-15 KVA UPS are available in the following configuration:
Stand Alone True Online UPS. (MX-S)
Dual Redundant Hot Standby type UPS. (MX-HS)
Parallel Redundant Load sharing type UPS.  (MX PRS)
 
Specifications
MAXIPOWER TECHNICAL SPECIFICATIONS
Models 0.5KVA 1KVA, 2KVA 3KVA 5KVA 6KVA 7.5KVA, 10KVA, 15KVA
AC Input Parameters AC Input Voltage
a)  230 V  -  20 % + 15 %
Single Phase or any Voltage Range as per Customer Requirement
Frequency a) 50Hz  ± 10 % can also Work on Good Quality Generators             
Acount Parameters a) Output Voltage 220 / 230 V AC Single Phase
b) Voltage Regulation ± 1 %
c) Frequency 50 Hz ± 0.05 Hz (Crystal Controlled)
d) Waveform Sine wave
e) Harmonic Distortion Less than 3 %
g) Power Factor 0.8 Lagging
h) Overload 110 % for 10 Minutes.200 % for 5 Cycles.
i) Crest Factor > 4 : 1
j) Transient Recovery Within 3 Cycles.
Protections Following Faults & Trips the System with Audio - Visual Indication.
a) Battery Over Voltage.
b) Battery Under Voltage.
c) Output AC Over Voltage.
d) Output Overload / Short Circuit.
Indications • Mains On.  • Load On Batteries.  • Battery Low.  • Inverter Overload. 
• Load On Mains.  • Battery Boost.  • Battery Level Graph  • Load Level Graph
Metering Ambient Conditions Digital Metering Available for Output Voltage / Battery Voltage / Output Current / Output Frequency (Customised Metering Option Available)
a) Operating - 0° C - 50° C.
b) Storage - 0° C - 60° C
c) Relative Humidity - 95 % RH.
d) Operating Altitude - upto 2000 Meters.
e) Audible Noise Less than 55 db at 1 Meter upto 10 KVA Less than 60 db at 1 Meter above 10 KVA
 
*The above system is based on normal standards and can be customised as per specifications
*For 180 V DC >92%, & for rest > 87 %
 
Optional Features :
Maxiline IGBT UPS provides upto 15 KVA power supply
Static Bypass Switch
Remote On / Off Panel
Remote Indicator Panel
SNMP Interface
Hot Standby Mode
Parallel Redundant Mode
 
The new generation energy from UNILINE is a complete green solution suitable for any enterprise, business houses, manufacturing units, institutions as well as domestic applications. Maxiline UPS systems fall in IGBT series of online UPS.