Call Us
+ 91-11-4666 1111
 
+ 91-11-2646 9031
 
+ 91-11-2646 9108
 
 
 
 
 
 
 
 

Uniplus 600VA

Line Interactive UPS
 
General Features :

Microprocessor control design guarantees high reliability.

Equipped with Boost and Buck AVR to stabilize input voltage.
Built-in DC start function enables UPS to be started up without AC power.
Auto Restart while AC recovery.
Compact size, Lght Weight.
Provides Overload Protection.
Provides Modem/ Phone Line Surge Protection/ USB Port. (Option)
 
Click here to download
Technical specification of Uniplus 600 VA
 
 

Smartpower

Line Interactive UPS (0.5 to 3 KVA)
 
The Standby Line Interactive UPS Systems from Uniline are Economical Datasaver and Manufactured with the Latest Power Conversion Techniques. Employed with excellent Line Filtering Devices PWM Technology used for Power Conversion with its Unique Single Transformer arrangement permits Lowest change over time, Greater System Effciency, Compact Size and High Reliability.

Indeed, an Intelligent 4-in-l standby UPS is just perfect for PCS, Pentium, Micro and Mini Computers, Peripherals, Biomedical Equipments etc.
 
Salient Features :

Very Wide Input Range.

Cold Start Facility, can be started during Power failure.
Input Filters for Line Noise and Spikes
Overload, Short Circuit Protection
RS 232 C Interface saves Data on Most Operative System. (Optional)
 
Smartline Technical Specifications
RATING   500 VA / 600 VA 625 VA / 650 VA 800 VA / 1000 VA 2000 VA
INPUT Voltage 140 V AC to 280 V AC
Frequency 50 Hz ± 6%
DC Voltage 12 V 24V 24 V / 48 V
OUTPUT Voltage 220 V + 9 % (Mains Mode)
220 V + 5 % (Battery Mode)
Frequency Same as Input (Under Mains Mode)
50 Hz ± 10% (Under Battery Mode)
BUILT - IN BATTERY (SMF)   1 x 12 V 7AH
EXTERNAL BATTERY   Charging Current Options Up to 20 Amps
MAX. CHARGING VOLTAGE   13.8 V 27.6 V 27.6 V / 55.2 V
90% RECHARGE TIME   3 to 4 hours
EFFICIENCY   AC TO AC > 95%
DC TO AC > 80%
PROTECTIONS   Short Circuit Electronic Shutdown
  Overload Electronic Shutdown
  Low Battery Electronic Shutdown
INDICATIONS   500 VA to 1 KVA UPS 1 KVA to 2 KVA UPS
  Load on AC AC On
  Load on DC DC On
  Over Load / LOW Battery Level
  Battery Trip Load Level Graph
COMMUNICATIONS   DB - 9 Female / R S 232 C / USB PORT (Optional)
ENVIRONMENT Temperature 0° C to 45° C
Humidity 30% to 95%
ACOUSTIC NOISE LEVEL   < 40 db at One Meter
 
Note : External Battery Model UPS for 1-4 hrs. Backup time are also available
* The above system are based on normal and can be customised as par specifications