Tri Power - IGBT Online UPS System (50 KVA to 200 KVA)

 
IGBT Online UPS System (50 KVA to 200 KVA)
MIMIC Panel
Display to provide instant view of UPS status. The LED’s quickly identify Input Power, Battery Status, Alarm Status. The LCD provides comprehensive information of Input & Output Voltage, DC Voltage, Current & Output Frequency. Front Panel also allows to control UPS.
 
Isolation Transformer
The isolation transformer at the output provides galvanic isolation. A UPS without isolation transformer at its output may cause danger to the connected loads in case there occurs a short circuit in the IGBT blocks of the inverter unit. In that case there is a high probability that the connected loads will be burnt or damaged due to high DC Voltage.

Another advantage of the galvanic isolation transformer is that it eliminates the peaks (electrical noise or instant peaks) that might appear at the phase, natural or earth line. For example, in a rainy day if there hits a lightning at the input, the electrical noise will not be able to pass through the output voltage. As a results the load remain safe.
 
Quality Standard & Awards :
ISO 9001 - 2000 for Quality
ISO 14001 for Environment
EN 50091 - 1 Safety
EN 50091 - 2 EMC
Udyog Pragati Award
National Quality Gold Star Award
Udyog Rattan Award
 
Power Factor Correction (PFC)
Optional
Power Factor Correction unit is available at the input stage of UNILINE 3 Phase UPS System. While the input power factor is around 0.8 in a normal device without PFC unit. The nearer the power factor to 1, the less electric bill is paid for the re-active power used. At the same time the system efficiency is enhanced and less current is drawn at the UPS Input. As the input current is less, you would be benefited while purchasing a generator with low current rating. Another advantage of using a UPS with PFC unit is that it does not distort the mains supply. As a result the other electronic devices connected to the mains run safely without any interruption.
 
Salient Features :

Wide Input Window

Generator Compatible
High Input Power Factor
Micro processor / DSP based design
Float Cum Boost Charger
IGBT based Hi - Frequency PWM Inverter
Soft Start Facility
Inverter Efficiency > 92%
Distoration Less Than 3%
Crystal Controlled Output Frequency (50 Hz ± 0.01%)
Low Noise < 55 db Up to 100 KVA
Output Isolation
High Crest Factor > 4:1
Compact, Sleek Design
Unlimited Backup
ETDC/ERTL Tested
 
ECO-Mode
Optional
Eco-mode is a low-cost UPS operational mode, which provides high efficiency (97 %) with respect to the user electric bill. If the bypass exists in the desired voltage range and the harmonic distortion is not so high, the loads can be fed from bypass instead of from inverter output. As soon as the bypass failure occurs, without any interruption the inverter output starts feeding the load. The user can also manually adjust the UPS to either Normal or Eco - Mode.
 
IGBT & PWM Technology
A widely used and developed semiconductor, IGBT (INSULATED GATE BIPOLAR TRANSISTOR), are used in the Inverter part of the UPS. With the Sinusoidal Pulse Width Modulation Technique, maximum operational efficiency is obtained and thus even the non - linear loads are fed with precise sinusoidal signal.
 
 
Parallel Configuration
Parallel configuration is a system, which ensures more sensitive and reliable operation of the UPS to continue feeding the loads. Because, in a parallel configuration even if one unit of the UPSs goes out of order, the other units still operate and thus ensures a continuous feeding of the load without transferring the load to bypass. In this system n+1 units can be connected in parallel and thus altogether increase the total capacity of the system. In this way, whenever necessary, the user can add an extra unit to feed a larger load system.
 
Hot stand by Configuration
Feed one (priority) or two (priority & normal) load banks depending on the application need.
Increase the reliability of the priority load.
Increase the maintainability.
Easy connection.
Can be implemented in the existing installation regardless of the UPS size, the generation
(of device, technology or control mechanism) and the manufacturer.
 
Optional Properties:
(n+1) parallel configuration
ECO-MOD Green Power
Remote Panel (observation and control)
SNMP VIEW
WAN / Internet Interface
Higher PFC
 
SNMP View Software
When the computers (connected to a network) need communicating with each other in order to exchange data among themselves, they are required to talk in the same “Language”. These sorts of Languages are termed as Protocol in computer and communication world and SNMP (Simple Network Management Protocol) is one of these protocols. The main purpose of using SNMP protocol is to administer Computers and other Network devices from one or more than one center. In order to watch the SNMP devices from one center, it is only possible with the aid of SNMP administration software programs. SNMP View Program is a Windows based network observation and administration software that facilitates observing all the SNMP devices connected to the network from one center. With the help of this software program the UPS devices can be monitored too. As soon as the UPS devices are connected to the network through SNMP adapters and their proper network settings are completed, the UPS devices are ready to send all their parameters to this software program. By using the main window of this software program, it is possible to observe SNMP compatible devices all over the country or all over the world at the same time. With the aid of developed listing options it is easy to administer the devices, to learn how many devices are there in a particular region or to obtain detail information of the devices just by one click of the mouse. As it is explained above, with the aid of this software program and by some clicks of your mouse, you can easily observe all the information belong to UPS devices remotely placed anywhere in the World. By SNMP View Program you can
observe and obtain detail information not only of UPS devices but also of all SNMP compatible network devices. SNMP view Program is prepared by UNILINE and supported with Windows 98, 2000, XP, NT, 2003, Linux, Free BSD, SUN OS, SUN Solaris, SUN Solaris X 86, HP PH-UX, DEC OSF/1, IBM AIX, UNIX and XENIX etc.
 
Uniline UPS Manager Network Software
UNILINE UPS Manager software family is developed order to observe UPS parameters from PC. These programs provide communication between the RS 232 port (COM port) of a PC and the RS 232 port of the UPS. Thus the information obtained can be observed easily on the PC monitor. With the aid of its serial communication port, the UPS can be connected either to the server or to one of the client computers. Uniline UPS Manager software is compatible with Windows 95, Windows XP and Windows NT workstation and Windows NT Server. UNILINE UPS Manager Software can also be used in a network containing more than one server. In such a case the UPS
can be connected to any one of the server or terminal computer provided that the compatible operating system is installed. UPS observation and control operations are done from this connected PC screen. Moreover, during mains failure server or terminal PCs can also be shutdown safely.
 
Technical Specifications
AC Input Parameters
AC Input Voltage
Nominal, 415 V, Three Phase, 4 Wire, Variation : 300 V - 470 V. Input Power Factor > 0.9
P.S. UPS with higher Input range can also be supplied on request.
Input Frequency
a) 50 Hz ± 10% or 60 Hz ± 10% Can also work on Generators
DC Output (Rectifier)
UPS Capacity DC Output Voltage (Nominal)
a) 50 KVA & above 432 V
b) 5 KVA to 50 KVA 180 / 240 / 360 V
P.S. System with other DC Voltage can also be supplied on request.
Output Parameters
a) Output Voltage (Nominal) 230 V AC Single Phase ( MAXIPOWER ) or
415 V AC Three Phase ( TRIPOWER
b) Voltage Stability ± 1 % for DC Input variation & Output load variations.
c) Frequency 50 Hz ± 0.05 Hz (Crystal Controlled) or
60 Hz ± 0.06 Hz or any optional Frequency
d) Waveform Sinewave
e) Harmonic Distortion Less than 3 %
f) Efficiency > 93 % for 360 V DC & above
>90 % for 180 V DC
g) Power Factor 0.8 lagging to unity
h) Overload 110 % for 10 minutes.
200 % for 5 cycles. 400 % for ½ cycles.
or as per customer’s requirement
i) Crest Factor > 4 : 1
j) Transient Recovery Within 3 cycles.
k) Phase Displacement for 3 Phase Output 120 0 ± 1 0
l) Audible Noise Less than 55 db at 1 metre upto 100 KVA
Less than 60 db at 1 metre upto 200 KVA
Self & Dignostic Features
An electronics circuit with digital logics continuously searches for the following faults & trips the system with audio - visual indication.
• Battery Over Voltage
• Battery Under Voltage
• Output AC Over Voltage
• Output Overload / Short Circuit
• Phase Fail for Three Phase models
Indicators
Mains On - Battery Boost - Load on Batteries - Inverter On - Battery Low - Load on Mains - Inverter Overload - 7 steps bar graph for Battery / Load Level
Ambient Conditions
• Operating : 0 °C - 50 °C • Storage : 0 °C - 60 °C • Relative Humidity : 95 % RH • Operating Altitude : upto 2000 meters
Metering
Digital Metering available for Input / Output Voltage / Battery Voltage / Battery Current / Output Frequency or any other parameters as per customer requirements.
Optional Features
Static By Pass Switch - Serial RS 232 Interface - Auto file Shut Down - Remote Indicator Panel - Microprocessor based Digital Metering - Remote On / Off Panel - SNMP Web Management Software
Our Other Products
• Line Interactive UPS • Constant Voltage Transformer • Servo Stabilizers • DC - AC (Sinewave Inverters) • Float Cum Booster Charger • Frequency Converters